Single-Containment/Full-Containment Tank

The capacity of LNG single-containment tank is generally 200 ~ 10,000m3. The single-containment tank has large fire protection distance, low land utilization rate and high investment cost of the owner; its storage tank has a vertical cylindrical structure, double walls, flat bottom and self-supporting dome, and the interlayer is filled with powder for heat insulation.

Product Description

Large LNG atmospheric pressure single-containment tank and full-containment tank.

With the promoted application of LNG clean energy, LNG storage tank is becoming larger and more applicable to atmospheric pressure. Large LNG storage tanks have been in widespread use in LNG liquefaction plants, LNG storage and distribution stations and LNG peak shaving stations.

The capacity of LNG single-containment tank is generally 200 ~ 10,000m3. The single-containment tank has large fire protection distance, low land utilization rate and high investment cost of the owner; its storage tank has a vertical cylindrical structure, double walls, flat bottom and self-supporting dome, and the interlayer is filled with powder for heat insulation.

The LNG full-containment tank features high safety, small fire protection distance and high land utilization rate. The single full-containment tank produced by the Company with a capacity of 5,000 ~ 50,000m3 is bimetallic and requires small investment and short construction cycle; the full-containment tank with a capacity of more than 50,000m3 are generally fully contained with concrete, requiring large investment and long construction period. The tank is bimetallic and has a vertical cylindrical body, inner ceiling, and outer dome with high thermal corner protection. Heat insulation method: The interlayer is filled with pearlite sand, elastic felt and foam glass brick.

Characteristics:

  • Henan Kylin Air Separation Group Co. Ltd.
  • Henan Kylin Air Separation Group Co. Ltd.
  • Henan Kylin Air Separation Group Co. Ltd.
  • Henan Kylin Air Separation Group Co. Ltd.
  • Henan Kylin Air Separation Group Co. Ltd.

Parameter

--Sample Models
Model (CFL/W) 500 1000 2000 3000 5000 8000 10000 20000 30000 50000
Structure Single capacity tanks : Ground high table, vertical cylindrical, internal and external tank arch support structure;Full capacity tank: inner tank ceiling, outer tank dome, more thermal Angle protection structure than single tank.
Inner tank/outer tank material Single capacity tanks:S30408/Q345R;Full capacity tank:S30408/S30408
Operating pressure 15~50 KPa
Inner tank size (m) 9.0 12.4 13.5 16.2 20.0 23.0 25.0 38.0 41.5 50.0
Outer tank size (m) 11.2 13.0 16.0 18.5 22.4 25.3 27.0 40.0 43.5 52.0